Supported Targets: E407
An 'Analog Output' block sets the 12-bit digital to analog conversion on the selected pin.
The value that needs to be converted to an analog voltage on the pin. This is a value from 0 to 4095 representing a voltage from 0 to 3.3V or 0.806mV per bit. The data type is uint16.
Parameter | Description |
---|---|
Output pin | The output pin to be used for the voltage output. Select one from the list. A warning will appear when the pin is already in use in another block. |
Sample time | Sample time of the block. The Sample time (in seconds) defines the rate at which the block is visited by the real-time scheduler of the target. The value of the Sample time has to be an integer multiple of the base sample time of the model. |