Supported Targets: Olimexino, E407, P405
The number active or stored errors is given, including the highest occurring severity level, assuming that the error's parameter was used for a severity level.
Output 1: Total number of errors, the number of different error codes that are currently active/stored.(uint8)
Output 2: Highest occurring severity. With this output it can be easily checked if the software should for example go to a safe mode.(uint8)
Parameter | Description |
---|---|
Active or stored error | The kind of error to be cleared. Active errors are still active at the moment and stored errors have happened before, although they could still be active. |
Sample time | Sample time of the block. The Sample time (in seconds) defines the rate at which the block is visited by the real-time scheduler of the target. The value of the Sample time has to be an integer multiple of the base sample time of the model. |
Delete error | Clear errors | Read active error | Read stored error | Search active error | Search stored error | Store error